or up to 12 months). Dissolve para-nitrophenyl phosphate (pNPP) in substrate buffer to a working concentration of 1 mg/mL. Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Supplementary Materials The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/mps5040054/s1 , Table S1: Analysis of callose concentration in the leaves, pseudostems and corms of banana plants inoculated and non-inoculated (control) with Xcm (Independent sample t-test, α ≤ 0.05). Click here for additional data file. Author Contributions Conceptualization, A.K.T.; methodology, A.S.M., A.K.T. and P.S.; validati
Open resource ↗lines:167-297Paper record
Sandwich Enzyme-Linked Immunosorbent Assay for Quantification of Callose.
Methods and protocols · 26 Jun 2022 · 10.3390/mps5040054
Abstract
The existing methods of callose quantification include epifluorescence microscopy and fluorescence spectrophotometry of aniline blue-stained callose particles, immuno-fluorescence microscopy and indirect assessment of both callose synthase and β-(1,3)-glucanase enzyme activities. Some of these methods are laborious, time consuming, not callose-specific, biased and require high technical skills. Here, we describe a method of callose quantification based on Sandwich Enzyme-Linked Immunosorbent Assay (S-ELISA). Tissue culture-derived banana plantlets were inoculated with Xanthomonas campestris pv. musacearum ( Xcm ) bacteria as a biotic stress factor inducing callose production. Banana leaf, pseudostem and corm tissue samples were collected at 14 days post-inoculation (dpi) for callose quantification. Callose levels were significantly different in banana tissues of Xcm -inoculated and control groups except in the pseudostems of both banana genotypes. The method described here could be applied for the quantification of callose in different plant species with satisfactory level of specificity to callose, and reproducibility. Additionally, the use of 96-well plate makes this method suitable for high throughput callose quantification studies with minimal sampling and analysis biases. We provide step-by-step detailed descriptions of the method.
Code and data availability